IDACT 2.1-14

November 8, 2017


INSIGHT DLP is pleased to announce the immediate release of IDACT (INSIGHT DLP Appliance Control Tools) version 2.1-14. This release adds support for Symantec DLP 14.6 MP2 and 15.0.0, and also provides a few feature enhancements along with some stability improvements for INSIGHT DLP Appliances running IDACT v2 ONLY.

 

Upgrade IDACT version

* Prior to applying the IDACT update please restart your appliances.

This will update the Appliance, Enforce, and all running Linux detection servers on the Appliance. Verify that all severs have internet access. Log in to each INSIGHT DLP Appliance and navigate to Device List. Click [Update] under System Management. Alternatively log in to the Appliance via SSH and issue the following command:

update

This will update the system to the latest version available of IDACT. 


-------------------------------------------------------------------------------------------------

NOTES: 

  • Symantec DLP 14.5 and later is not supported on IDACT v1.x Appliances and some early versions of IDACT v2.x (v2.0-x to 2.1-6). Please contact support if you are running IDACT v1 or have any concerns about the version you are running. To quickly check, log in to your Enforce or a Detection server (not the appliance itself) and run:
    cat /etc/redhat-release
    and
    cat /etc/IDACT-release

    If the output indicates CentOS 5.x and IDACT 2.1-6 or earlier, then Symantec DLP 14.5 or better will not run.

  • This IDACT Update will NOT upgrade your DLP release. This will update the underlying OS and IDACT software. Instructions for updating Symantec DLP on the INSIGHT Appliance are available in the Administration guide for your applicable version. The latest version of these documents are available within the support portal (INSIGHT 15.0 Upgrade Guide).

  • Before attempting an upgrade of the Symantec DLP software application and/or the INSIGHT DLP Appliance IDACT firmware, infoLock Technologies and INSIGHT DLP strongly recommend that customers check the INSIGHT DLP Appliance Support Matrix to determine if the desired version is supported on their model appliance. Failure to abide by the supportability matrix may put a customer’s INSIGHT DLP Appliances into an unsupported configuration and could result in incompatibility-related issues or failures.

  • If the Web UI does not start after the update, log in via SSH as appuser and run:
    service_restart 

Obtaining Support
If you require technical assistance with this issue, have any questions, or require further information, please contact the INSIGHT Support Team at support@insightdlp.com or via http://insightdlp.com/support

Regards,

INSIGHT Support Team
support@insightdlp.com

-------------------------------------------------------------------------------------------------
Change Log

IDACT 2.1-14
* DLP
 - Added support for Symantec DLP 15.0.0
 - Added support for Symantec DLP 14.6 MP2 and 15.0.0 Detection server (SMTP) hotfix
 - Added detection server support for Stunnel and OpenSSL patch to support SICAP
 - Added fix for Appliance Web UI hostname to not allow special characters